Roche Rapid Antigen Self Test

WE STOCK AND SELL BULK ROCHE RAPID ANTIGEN TESTS FOR BUSINESSES. WE HAVE WAREHOUSES IN SYDNEY, MELBOURNE, BRISBANE AND GOLD COAST WITH SHIPPING AVAILABLE AUSTRALIA WIDE
Please contact us for order enquiries

Roche SARS-CoV-2 Antigen Self Test Nasal

Roche SARS-CoV-2 Antigen Self Test Nasal

1 Carton (117 kits) $5499+GST
8+ Cartons contact for price
24+ Cartons contact for price
Email order
Minimum order of 1 Carton

TESTING IN YOUR HANDS

Quick results

Quickly determine in 15 minutes whether you may be infected with COVID-19 from the comfort of your Home or Workplace. If you test positive, a PCR test is required.

Easy to use

As the swab only has to be inserted into the lower nasal cavity, collection of the sample is relatively simple and comfortable. All the necessary materials are included within the kit, with only a couple of quick and straight forward steps required to complete the test.

Reliable results

The test determines your infection status with a high level of accuracy and precision. Results have been analysed across many SARSCoV-2 variants, with no change in accuracy. Approved for use by the Australian Government.

How to use the test kit

Performing a self test using the SARS-CoV-2 Antigen Self Test Nasal

FOUR STEPS TO YOUR RESULTS

1. Take a sample

Wash your hands before performing the test. Take the swab out of the packaging, being careful to only touch the swab by the handle. Tilt your head back slightly. Insert the swab into one nostril. Slowly push the swab forward about 2 cm (parallel to the roof of your mouth) until you feel resistance. Do not apply any pressure. Turn the swab 4 times (for a total of approx. 15 seconds) against the inside of the nose and then remove it from the nose. Repeat with the same swab in the other nostril.

2. Dissolve the sample (in the extraction buffer)

Place the swab in a tube with extraction buffer. Squeeze the tube at the bottom and turn the swab back and forth more than 10 times. Continue to squeeze the sides of the tube while removing the swab to force all of the liquid out of the swab. Press the dispenser cap firmly onto the tube.

3. Apply the dissolved sample to the test cassette

Place the test strip on a flat surface. Hold the tube vertically over the round marked area (not the rectangular result window). Drop exactly 4 drops on the field. To do this, gently squeeze the tube if necessary.

4. Check the result

Set a timer and read the test result after 15-30 minutes. If the test result is read after more than 30 minutes, the result may be incorrect.

FREQUENTLY ASKED QUESTIONS

GENERAL QUESTIONS

The SARS-CoV-2 Antigen Self Test Nasal is a lateral flow test. It can help to detect antigens of the SARS-CoV-2 virus from nasal samples in individuals who are suspected of having COVID-19.

The course of SARS‑CoV‑2 infections can vary widely. Some people do not have any symptoms, others experience mild symptoms such as fever, cough, loss of taste or smell, or diarrhoea. But it can also cause more serious symptoms such as difficulty in breathing3. Usually, it takes 5 – 6 days for symptoms to develop after an exposure to SARS‑CoV‑2, but sometimes it can take as long as 14 days4.

The test can help you to quickly and easily determine whether you might be infected with SARS-CoV-2 or not. You can test yourself from the comfort of your home and you do not need any specific training as it is easy to perform.

COVID-19 antigen tests perform best when the viral load is at its highest during an infection. Outside of this window, such as at the start of the infection, or late infection, the test may not detect the virus. Therefore, regular testing (such as every few days) increases the chance of detecting COVID-19. Please refer to your local state/territory health department for further guidance on this topic.

No, according to our instructions for use, the test must be performed by an adult or under close adult supervision on children under 18 years of age.

At the moment, the SARS-CoV-2 Antigen Self Test Nasal test is only available in packs of 5.

For customer notifications relating to all the lateral flow tests (including the SARS-CoV-2 Antigen Self Test Nasal) please contact Roche on 1800 497 069 9am-7pm AEST / 9am-8pm AEDT, 7 days per week, or by completing this form.

The most recent version of the Instructions for Use and Quick Reference Guide for the SARS-CoV-2 Antigen Self Test Nasal can also be found here.

KIT COMPONENTS

Each test kit contains everything you need in order to perform 5 tests. The components that you need to perform a test are:

  • Test device
  • Buffer tube
  • Nozzle cap
  • Sterile swab
  • Tube holder
  • Instructions for use and Quick Reference Guide

In this case, do not use the damaged test kit and use a new one. We would also recommend you report the damaged kit to wherever you got the test kit. Additionally, we would recommend you report the incident on 1800 497 069 9am-7pm AEST / 9am-8pm AEDT, 7 days per week or by completing the form below.

TEST SPECIFICATIONS

The test has a shelf life of 24 months from the manufacturing date. The manufacturing and expiry date can be found on the back of the kit box or also on the back of the foil pouches inside the test kit.

No, the test should not be used anymore when the expiry date has passed. Please use a new in date test.

The test device can be used for a maximum of one hour after opening the sealed packaging. If the test device has been out of the sealed foil pouch for more than one hour, you should not use it anymore. Please use a new test.

Any COVID-19 variants in circulation as of 13 September 2021 are detected by this test without any impact on performance.

Didn't find what you're looking for?

Refer to the Roche product page or call their technical support on
1800 497 069 9am-7pm AEST / 9am-8pm AEDT, 7 days per week

We also sell Panbio Abbott Rapid Antigen Self Tests  – click here to find out more.